Request a Quote for Part 07-00140-002 with the NSN 5925008410679 by Texas Instruments Inc
Circuit Breaker
07-00140-002 procurement notes
If you are interested in 07-00140-002 with NSN 5925008410679, we have you covered with available parts to purchase on Aviation Domain 360. Circuit Breaker is listed alongside the part number 07-00140-002 under FSC , having been manufactured by Texas Instruments Inc. If you would like to receive a quote on this item for your comparisons, please fill out and submit the RFQ form below with as much detail as you can provide. With the information that you offer, our team members will quickly craft you a personalized solution that takes your individual needs and requirements into account. As our team members are always available for customers 24/7x365, responses to RFQ submissions will be given in just 15 minutes or less.
Alongside CAGE Code parts from Texas Instruments Inc, we also provide items from countless leading global manufacturers that we trust as a part of our NO CHINA SOURCING pledge. Prior to shipment, numerous products are subjected to rigorous quality assurance measures, ensuring their reliability and caliber. Furthermore, all items ship alongside their qualifying certifications and manufacturing trace documentation as applicable. As a result of our practices, we are AS9120B, ISO 9001:2015, and FAA AC 00-56B certified and accredited. Get started with a competitive quote for NSN 5925008410679 and see why customers steadily depend on Aviation Domain 360 for all their operational needs.
Reference data
Sourcing more than one part?
Upload a bill of materials (BOM) or paste a list of part numbers — every line bundles into a single RFQ. No checkout, no payment.
- AS9120:2025· Aerospace QMS
- ISO 9001:2015· Quality Management
- FAA AC 00-56B· Voluntary Industry Distributor Accreditation
- U.S. ONLY· Fulfillment
NSN Information for Part Number 07-00140-002 with NSN 5925-00-841-0679, 5925008410679
Characteristics Data of NSN 5925-00-841-0679, 5925008410679
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| ABXD | BUSHING LENGTH | 0.281 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 0.850 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 2.000 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 2.765 INCHES MAXIMUM |
| ADTV | CASE MATERIAL | PLASTIC |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.750 INCHES NOMINAL |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.625 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.750 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.810 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 3 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING AND 4 THREADED HOLE |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CMLP | THREAD QUANTITY PER INCH | 32 AND 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES AC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 800.0 AC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 145.0 ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| CQJX | NOMINAL THREAD SIZE | 0.375 INCHES AND 0.138 INCHES |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 4.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 35.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| THSD | THREAD SERIES DESIGNATOR | UNEF AND UNC |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB W/SCREW |