Request a Quote for Part 428605 with the NSN 6630012346794 by Qbc Diagnosticsinc
Special Features: Microprocessor controlled electro-optical instrument for measuring packed cell volumes and converting to relative values;components INC.75X monocular microscope, rotating tube cartridge assy;opical encoder;uv illuminator lamp;various lenses and filters to cause stained white cells and platelets to FLUORESCE;12 place hematocrit centrifuge with head cover, fixed five minute TIMER;12, 000 rpm speed capacity;and rcf of 14, 387 X g;two position pipetter with fixed volume of 111.1 microliters;work station with numbered slots for capillary tubes;wells for whole blood tubes and rack for storage of pipetter;operation method:electric;exterior container QUANTITY:1;THE number of alternating current phase:two Current Type: AC Voltage IN Volts: 120.0 and 220.0
428605 procurement notes
If you are interested in 428605 with NSN 6630012346794, we have you covered with available parts to purchase on Aviation Domain 360. Special Features: Microprocessor controlled electro-optical instrument for measuring packed cell volumes and converting to relative values;components INC.75X monocular microscope, rotating tube cartridge assy;opical encoder;uv illuminator lamp;various lenses and filters to cause stained white cells and platelets to FLUORESCE;12 place hematocrit centrifuge with head cover, fixed five minute TIMER;12, 000 rpm speed capacity;and rcf of 14, 387 X g;two position pipetter with fixed volume of 111.1 microliters;work station with numbered slots for capillary tubes;wells for whole blood tubes and rack for storage of pipetter;operation method:electric;exterior container QUANTITY:1;THE number of alternating current phase:two Current Type: AC Voltage IN Volts: 120.0 and 220.0 is listed alongside the part number 428605 under FSC , having been manufactured by Qbc Diagnosticsinc. If you would like to receive a quote on this item for your comparisons, please fill out and submit the RFQ form below with as much detail as you can provide. With the information that you offer, our team members will quickly craft you a personalized solution that takes your individual needs and requirements into account. As our team members are always available for customers 24/7x365, responses to RFQ submissions will be given in just 15 minutes or less.
Alongside CAGE Code parts from Qbc Diagnosticsinc, we also provide items from countless leading global manufacturers that we trust as a part of our NO CHINA SOURCING pledge. Prior to shipment, numerous products are subjected to rigorous quality assurance measures, ensuring their reliability and caliber. Furthermore, all items ship alongside their qualifying certifications and manufacturing trace documentation as applicable. As a result of our practices, we are AS9120B, ISO 9001:2015, and FAA AC 00-56B certified and accredited. Get started with a competitive quote for NSN 6630012346794 and see why customers steadily depend on Aviation Domain 360 for all their operational needs.
Reference data
Sourcing more than one part?
Upload a bill of materials (BOM) or paste a list of part numbers — every line bundles into a single RFQ. No checkout, no payment.
- AS9120:2025· Aerospace QMS
- ISO 9001:2015· Quality Management
- FAA AC 00-56B· Voluntary Industry Distributor Accreditation
- U.S. ONLY· Fulfillment
Characteristics Data of NSN 6630-01-234-6794, 6630012346794
| MRC | Criteria | Characteristic |
|---|---|---|
| AKYD | ACCESSORY COMPONENTS AND QUANTITY | ELECTRO-OPTICAL MAGNIFICATION READER 1; WORK STATION 1; VENOUS-BLOOD PIPETTER 1 |
| ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| ALUE | UNIVERSAL MEDICAL DEVICE NOMENCLATURE SYSTEM CODE | 16298 |
| ELEC | VOLTAGE IN VOLTS | 120.0 AND 220.0 |
| SUPP | SUPPLEMENTARY FEATURES | CONT C/O TWO SEALED CALIBRATION CHECK TUBES; ONE VENOUS,ONE CAPILLARY; ONE PAIR FORCEPS; SPARE PIPETTER "O" RINGS AND GREASE,SPARE LAMPS FUSES,TWO THRUST PIVOTS,ONE 5/64 IN. HEX KEY AND TEST GUIDE; CAPABLE OF PERFORMING THE FOLLOWING QUANTITATIVE FUNCTIONS ON A CENTRIFUGAL BLOOD TUBE; HEMOGLOBIN,HEMATOCRIT,PLATELET COUNT,WHITE BLOOD COUNT,GRANULOCYTE COUNT,AND LYMPHOCYTE-MONOCYTE COUNT; FOR CAPILLARY MICROHEMATOCRIT TUBE KIT ORDER 6630-01-233-7594; FOR VENOUS MICROHEMATOCRIT TUBE KIT,ORDER 6630-01-233-7593 AND VENOUS HEMATOCRIT TUBE KIT 6630-01-233-9592; REQUISITIONER SHOULD SPECIFY THE VOLTAGE AND FREQUENCY REQUIRED |
| ACDC | CURRENT TYPE | AC |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | ANALYZER, CLINICAL CHEMISTRY |
| FEAT | SPECIAL FEATURES | MICROPROCESSOR CONTROLLED ELECTRO-OPTICAL INSTRUMENT FOR MEASURING PACKED CELL VOLUMES AND CONVERTING TO RELATIVE VALUES;COMPONENTS INC.75X MONOCULAR MICROSCOPE,ROTATING TUBE CARTRIDGE ASSY;OPICAL ENCODER;UV ILLUMINATOR LAMP;VARIOUS LENSES AND FILTERS TO CAUSE STAINED WHITE CELLS AND PLATELETS TO FLUORESCE;12 PLACE HEMATOCRIT CENTRIFUGE WITH HEAD COVER,FIXED FIVE MINUTE TIMER;12,000 RPM SPEED CAPACITY;AND RCF OF 14,387 X G;TWO POSITION PIPETTER WITH FIXED VOLUME OF 111.1 MICROLITERS;WORK STATION WITH NUMBERED SLOTS FOR CAPILLARY TUBES;WELLS FOR WHOLE BLOOD TUBES AND RACK FOR STORAGE OF PIPETTER;OPERATION METHOD:ELECTRIC;EXTERIOR CONTAINER QUANTITY:1;THE NUMBER OF ALTERNATING CURRENT PHASE:TWO |