Request a Quote for Part 004948 with the NSN 5950003143631 by Phoenix Transformer Co
Transformer Power
004948 procurement notes
If you are interested in 004948 with NSN 5950003143631, we have you covered with available parts to purchase on Aviation Domain 360. Transformer Power is listed alongside the part number 004948 under FSC , having been manufactured by Phoenix Transformer Co. If you would like to receive a quote on this item for your comparisons, please fill out and submit the RFQ form below with as much detail as you can provide. With the information that you offer, our team members will quickly craft you a personalized solution that takes your individual needs and requirements into account. As our team members are always available for customers 24/7x365, responses to RFQ submissions will be given in just 15 minutes or less.
Alongside CAGE Code parts from Phoenix Transformer Co, we also provide items from countless leading global manufacturers that we trust as a part of our NO CHINA SOURCING pledge. Prior to shipment, numerous products are subjected to rigorous quality assurance measures, ensuring their reliability and caliber. Furthermore, all items ship alongside their qualifying certifications and manufacturing trace documentation as applicable. As a result of our practices, we are AS9120B, ISO 9001:2015, and FAA AC 00-56B certified and accredited. Get started with a competitive quote for NSN 5950003143631 and see why customers steadily depend on Aviation Domain 360 for all their operational needs.
Reference data
Sourcing more than one part?
Upload a bill of materials (BOM) or paste a list of part numbers — every line bundles into a single RFQ. No checkout, no payment.
- AS9120:2025· Aerospace QMS
- ISO 9001:2015· Quality Management
- FAA AC 00-56B· Voluntary Industry Distributor Accreditation
- U.S. ONLY· Fulfillment
NSN Information for Part Number 004948 with NSN 5950-00-314-3631, 5950003143631
Characteristics Data of NSN 5950-00-314-3631, 5950003143631
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.859 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.859 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT400.0 HERTZ MAXIMUM SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 3.063 INCHES NOMINAL3.063 INCHES NOMINAL |
| ADAT | BODY WIDTH | 2.625 INCHES NOMINAL2.625 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 3.188 INCHES NOMINAL3.188 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT4 SECONDARY SINGLE COMPONENT |
| CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 0.3 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 0.3 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 0.6 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 25.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 210.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 210.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY42.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 42.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY210.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 42.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 11 TURRET |