Request a Quote for Part 5SE01330-16 with the NSN 5925013983242 by Battenfeld Technologies Inc
Circuit Breaker
5SE01330-16 procurement notes
If you are interested in 5SE01330-16 with NSN 5925013983242, we have you covered with available parts to purchase on Aviation Domain 360. Circuit Breaker is listed alongside the part number 5SE01330-16 under FSC , having been manufactured by Battenfeld Technologies Inc. If you would like to receive a quote on this item for your comparisons, please fill out and submit the RFQ form below with as much detail as you can provide. With the information that you offer, our team members will quickly craft you a personalized solution that takes your individual needs and requirements into account. As our team members are always available for customers 24/7x365, responses to RFQ submissions will be given in just 15 minutes or less.
Alongside CAGE Code parts from Battenfeld Technologies Inc, we also provide items from countless leading global manufacturers that we trust as a part of our NO CHINA SOURCING pledge. Prior to shipment, numerous products are subjected to rigorous quality assurance measures, ensuring their reliability and caliber. Furthermore, all items ship alongside their qualifying certifications and manufacturing trace documentation as applicable. As a result of our practices, we are AS9120B, ISO 9001:2015, and FAA AC 00-56B certified and accredited. Get started with a competitive quote for NSN 5925013983242 and see why customers steadily depend on Aviation Domain 360 for all their operational needs.
Reference data
Sourcing more than one part?
Upload a bill of materials (BOM) or paste a list of part numbers — every line bundles into a single RFQ. No checkout, no payment.
- AS9120:2025· Aerospace QMS
- ISO 9001:2015· Quality Management
- FAA AC 00-56B· Voluntary Industry Distributor Accreditation
- U.S. ONLY· Fulfillment
NSN Information for Part Number 5SE01330-16 with NSN 5925-01-398-3242, 5925013983242
Characteristics Data of NSN 5925-01-398-3242, 5925013983242
| MRC | Criteria | Characteristic |
|---|---|---|
| ADTV | CASE MATERIAL | PLASTIC |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 40.0 AMPERES AC ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
| CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| THSD | THREAD SERIES DESIGNATOR | UNC |
| AAQL | NULL | NULL |
| ADAQ | BODY LENGTH | 2.500 INCHES NOMINAL |
| ADAT | BODY WIDTH | 2.250 INCHES NOMINAL |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.062 INCHES NOMINAL |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.471 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 3 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
| AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| AJEC | BOSS HEIGHT | 0.140 INCHES NOMINAL |
| CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.938 INCHES NOMINAL |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 5.000 MINIMUM AT 200 PCT AND 25.000 MAXIMUM AT 200 PCT ALL LOCATIONS |